Kā darbojas krāsns un kā tā sevi ieslēdz un izslēdz

Bieži vien labākais veids, kā noskaidrot, kas ar kaut ko nepareizu, ir zināt, kā tam vajadzētu darboties. Ja jūs zināt darbību secību, varat precīzi noteikt, kur secība tiek traucēta. Jūsu krāsns nav izņēmums no noteikuma.

Kad termostats iedarbina jūsu krāsni, ir atskaņa un iemesls procedūrai, ko tā veic, droši ieslēdzot sevi. Nākamreiz, kad jūsu krāsns nereaģēs uz zvanu, jūs varēsiet redzēt, kur atrodas problēma, un jūs varat vai nu izlemt, vai tās labošana ir jūsu prasmju un resursu robežās, vai arī jums ir nepieciešams profesionāls HVAC tehniķis. jautājums jums.

Šī diskusija var ietaupīt jūsu laiku un naudu neatkarīgi no tā, vai pats novēršat problēmu, vai arī galu galā parādīsit problēmu savam servisa tehniķim.

Dedzināšanas kārtība: Mūsdienu piespiedu gaisa krāsns darbības soļi

Kad termostats prasa siltumu, krāsns sāk darboties, izejot no tālāk aprakstītajām pakāpēm un komponentiem. Daudzus no šiem komponentiem varat redzēt videoklipā.

  1. Termostats liek krāsnim ieslēgties.
  2. Indukcijas motors iedarbojas.
  3. Spiediena slēdzis apstiprina skursteņa pareizu ventilāciju.
  4. Karstās virsmas aizdedzes modulis (ja tāds ir, nevis dzirksteļaizdedzinātājs vai pilots) sāk mirgot.
  5. Gāzes vārsts tiek atvērts, un gāzi aizdedzina aizdedzes avots.
  6. Liesmas sensors pārbauda, ​​vai gāze ir iedegta.
  7. Augstas robežas slēdzis sasniedz iestatīto temperatūru.
  8. Iedegas pūtēja motors.
  9. Krāsns darbojas, līdz termostats ir apmierināts, un liek tai izslēgties.
  10. Gāzes vārsts izslēdzas.
  11. Augstas robežas slēdzis sasniedz zemās temperatūras iestatījumu.
  12. Ventilators izslēdzas.

Jaunākā krāsnī var būt vēl vairāk zvanu un svilpu; vecā krāsnī var būt tikai minimums, gāzes vārsts un termoelements (piemēram, vecmodīgs liesmas sensors). Termopāra vai liesmas sensors pārbauda, ​​vai pilots ir iedegts, un aptur, ja galvenais gāzes vārsts neatveras. Protams, salauzts termoelements var arī apturēt gāzes vārsta atvēršanos.

Termostats

Termostats ir tas, no kura viss sākas. Termostats faktiski ir tikai slēdžu komplekts, kas tiek atvērts un aizvērts atkarībā no temperatūras, ļaujot jaudai plūst uz noteiktām apkures un dzesēšanas sistēmas ķēdēm. Padomājiet par tiem kā par tiltiņiem, kas šūpojas augšup un lejup. Parasti tie ir sastādīti, bet tos var nolaist, lai aizvērtu tiltu un ļautu elektrībai iziet.

Kad jūsu mājās pazeminās temperatūra, termostats nomet savu tiltu, sūtot enerģiju uz krāsni, lai tā zinātu, ka ir nepieciešams siltums. Kad istabas temperatūra atkal paaugstinās, termostats paceļ savu tiltu un izslēdz strāvu. Gaisa kondicionēšanai termostats darbojas tāpat kā spoguļattēlā, aizverot tā tiltu, kad māja kļūst pārāk silta.

Ja temperatūra mājā ir zemāka par temperatūru, kurai iestatījāt termostatu, iespējams, ka jūsu termostats nedarbojas tā, kā vajadzētu. To varat pārbaudīt, lecot (pieskaroties kopā) sarkanajiem un baltajiem vadiem pie sava termostata. Ja krāsns ieslēdzas, iespējams, ka problēma ir jūsu termostats.

Ko dara vadi termostatā?

Citas vadu krāsas mājas sistēmā var būt paredzētas papildu funkcijām vai izmantošanai nākotnē.

Vada krāsaKo tas kontrolē

sarkans

Sarkans ir paredzēts spēkam. Tam ir 24 voltu jauda, ​​ko piegādā krāsns. Šī vara gaida pie “tilta”, līdz tiek pateikts, kurp doties.

Balta

Balta krāsa ir paredzēta siltumam. Kad tilts (slēdzis) starp sarkanajiem un baltajiem vadiem aizveras, termostats prasa siltumu.

Dzeltens

Dzeltenais ir dzesēšanai. Kad tilts (slēdzis) starp sarkanajiem un dzeltenajiem vadiem aizveras, termostats prasa dzesēšanu.

Zaļš

Zaļais ir ventilatoram. Kad tilts starp sarkano un zaļo aizveras, darbojas tikai ventilators. Nav nepieciešama apkure vai dzesēšana.

Zils

Zilā krāsa ir negodīga vai savvaļas karte. To var izmantot, lai darbinātu displeju vai uzlabotas funkcijas. Parasti tas tomēr tiek iesaiņots atpakaļ sienā un vispār netiek izmantots.

Induktora motors un ventilators

Induktora motors un ventilators izplūst izplūdes gāzu skurstenī, atbrīvojoties no oglekļa monoksīda (CO). Vecākas sistēmas šo gāzu izvadīšanai paļāvās tikai uz "dabisko vilkmi", taču induktori ir lielisks papildinājums krāsns sistēmai. Tie pagarina skursteņu kalpošanas laiku, un, lietojot tos ar spiediena slēdžiem, tie palīdz novērst saindēšanos ar CO.

Viktorīna

Par katru jautājumu izvēlieties labāko atbildi. Atbildes taustiņš ir zemāk.

  1. Cik cilvēku katru gadu ir ievainoti no CO?
    • 2,500
    • 10,000
    • 50,000
    • 100,000
  2. Cik cilvēku gadā mirst no CO?
    • 250
    • 750
    • 1,000
    • 1,500

Atbildes atslēga

  1. 10,000
  2. 1,500

Spiediena slēdži

Spiediena slēdža funkcija ir pārbaudīt, vai induktora motors faktiski virzās gaisu augšā uz skursteni. Ja skursteni aizsprosto, piemēram, putna ligzda, spiediena slēdzis izslēdz sistēmu, lai novērstu CO iekļūšanas risku mājās. Protams, spiediena slēdzis var arī izslēgties, ja motors ir vecs un darbojas pārāk lēni, lai apmierinātu slēdzi, vai šļūtene no ventilatora līdz slēdzim ir saspiesta vai salauzta, vai arī pats slēdzis ir slikts.

Karstās virsmas aizdedzinātājs

Atkal diezgan vienkārša ierīce sarežģītā sistēmā. Karstais virsmas aizdedzinātājs izmanto elektrisko enerģiju, lai ļoti trauslu keramikas elementu, kas līdzīgs oglēm, izskatītu tik augstā temperatūrā, ka, plūstot, dabasgāze vai propāns uzliesmo. Karstās virsmas aizdedzinātājs atrodas pie spraugas pie pirmā degļa pieslēgvietas, lai uzreiz iedegtu gāzi, kad tā nonāk ievadā. Tas novērš nedegušās gāzes uzkrāšanos ierīcē.

Dažās krāsnīs tiek izmantota tā saucamā dzirksteļaizdedze. Sarkanā karstuma virsmas vietā dzirksteļaizdedzinātājs rada virkni dzirksteļu, lai aizdedzinātu gāzi.

Nav svarīgi, vai jūsu krāsnī ir karstas virsmas vai elektroniska aizdedze; svarīgi ir tas, ka jūs izvairāties no signāllampas izmantošanas. Izmēģinājuma gaismas izplūdes gāzēs; apkures sezonā viņi pastāvīgi sadedzina gāzi, un daži cilvēki ļauj tiem degt visu gadu.

Vai vēlaties ietaupīt dažus dolārus? Pārliecinieties, ka esat izslēdzis savas krāsns pilotu, kad tas netiek izmantots sezonā. Vienkārši pārliecinieties, ka zināt, kā nākamgad to atjaunot.

Gāzes vārsts

Gāzes vārsts būtībā ir elektroniski vadāms vārteja. Kad iekārta prasa siltumu, un shēma apstiprina, ka ir izpildīti pareizie nosacījumi, iekārta enerģiju nodod vārstam, liekot tai atvērt un atbrīvot gāzi, ko aizdedzinātājs vai pilots aizdedzina. Kad siltuma cikls ir noritējis, enerģija vārstam tiek pārtraukta, un vārsts atkal izslēdzas, pārtraucot gāzes padevi degļiem.

Liesmas sensors

Liesmas sensors ir ļoti vienkāršs, tomēr rada daudz problēmu māju īpašniekiem. Tās vienīgais uzdevums ir pārbaudīt, vai gāze ir iedegta, sajūtot siltumu. Ja nav siltuma, tas izslēdz gāzi, lai izvairītos no bīstamas gāzes uzkrāšanās ierīcē. Liesmas sensoru ir viegli salabot, ja tas iet slikti vai tam vienkārši nepieciešams kāds TLC.

Es uzrakstīju vienkāršu soli pa solim ceļvedi cilvēkiem, kam jātīra krāsns liesmas sensors. Apskatiet - daudz problēmu var novērst, vienkārši notīrot liesmas sensoru.

Video: Liesmas sensora tīrīšana

Augsta līmeņa slēdzis

Augstas robežas slēdzim ir vairāki mērķi. Pirmkārt, tas novērš krāsns ventilatora ieslēgšanos, līdz tiek konstatēts, ka ir sasniegta iestatītā temperatūra. Pretējā gadījumā ventilators ieslēdzas priekšlaicīgi un katru reizi, kad termostats prasa siltumu, mājā iepūta aukstu gaisu.

Otrkārt, tas arī pūtējam norāda, cik ilgi tam vajadzētu turpināt darboties pirms izslēgšanās, kad termostats ir apmierināts. Pretējā gadījumā karstais gaiss, kas paliek cauruļvadā un siltummainī, pēc krāsns atslēgšanas vienkārši izšķiestu.

Visbeidzot, lai novērstu bīstamu pārkaršanu, slēdzis izslēdz ierīci, ja siltummainis sasniedz noteiktu augstu temperatūru.

Krāsns ventilators un ventilatora motors

Ak, beidzot. Siltums mums visiem. Tagad, kad visi sensori ir apmierināti, un gala slēdzis pūtējam norāda, ka gaiss ir pietiekami silts, lai to varētu ievietot dzīvojamā telpā, tas sāks gaisu plūst.

Mūsu krāsns ventilators parasti izmanto 120 voltus un nospiež jebkur no 800 līdz 2000 kubikpēdām minūtē (cfm). Lielākajai daļai pūtēju ir nepieciešams izmantot kondensatoru, un tiem ir pus collu piedziņa, kas tiek piestiprināta tieši pie ventilatora, ja vien jums nav motora ar siksnas piedziņu.

Tid-Bit: Nepareizas darbības vai ierīces strāvas padeves pārtraukuma gadījumā parasti pūtējs ieslēdzas un darbojas noteiktu laika periodu. Tas var notikt tāpēc, ka ir pārāk daudz siltuma un ir nepieciešama atdzišana, vai arī var veidoties "sliktas gāzes", kuras ventilatoram jāizplūst vai jāizkliedē.

Izskrējiena slēdzis

Ietaupiet laiku un naudu, zinot savu krāsni

Es ceru, ka tas jums palīdzēja mazliet labāk izprast jūsu apkures sistēmu. Šeit ir dažas problēmu novēršanas idejas, kas saistītas ar tikko izlasītajām daļām, un šeit ir vēl daži padomi par daļām.

  • Nepareizas darbības gadījumā jūsu krāsns parasti mēģina restartēt trīs reizes. Ja trešajā mēģinājumā tas nevar sasniegt veiksmīgu aizdedzi, tas ieslēdzas bloķēšanas režīmā uz noteiktu laiku, parasti stundu. Strāvas atiestatīšana (izslēgšana un ieslēgšana) parasti atiestatīs dēli un ļaus vienībai parādīt, kas notiek, ja jūs to nokavētu.
  • Mazā mirgojošā gaisma ierīcē nav Ziemassvētku rotājums vai maza diskotēka jūsu krāsnī. Šī gaisma mirgo sava veida Morzes kodā, kas var novest jūs pie problēmas vai teikt "Hei, šeit viss ir kārtībā". Paskaties iekšā un ārpus ierīces. Visticamāk, ir kodu diagramma, kas norāda, ko nozīmē redzamā punkta, punkta, domuzīmes, domuzīmes secība.
  • Daži nepatīkami trokšņi, ko rada jūsu mājas krāsns, var būt vienkārši un lēti nomierināties.
  • Rūpējieties par savu krāsni, un tā, iespējams, rūpēsies par jums. Bet, ja jūs netīriet ierīci un nemaināt filtru, kā paredzēts, krāsns var sabojāties vai sabojāt banku.

Jautājumi un atbildes

Jautājums: Kāda varētu būt problēma, kad sildītājs izslēdzas un pēc dažām stundām tiek restartēts?

Atbilde: Problēma var būt daudzas lietas. Šī “bloķēšana”, kurā notiek krāsns, ir noklusējums pēc 3 secīgām kļūmēm. Diemžēl tas man nepasaka, kāda ir neveiksme.

Jautājums: Vai vakar vakarā bija iznācis tehniķis, kurš mainīja dažas lietas, un tagad siltummainis spīd?

Atbilde: Vai esat pārliecināts, ka tas ir siltummainis? Es drīzāk šaubos, ka tas kļūst pietiekami karsts, lai spīdētu, neizlaižot hi-limit slēdzi.

Jautājums: Krāsns cikli darbojas un darbojas labi, bet pūtējs neizslēdzas un turpina pūst aukstu gaisu. Ko man darīt?

Atbilde: Šķiet, ka termostata vads, parasti zaļais, kaut kā pieskaras citam vadam, iespējams, sarkanam, un uztur ventilatoru visu laiku. Vai arī jūsu statuss ir iestatīts uz “ventilators”, nevis “automātisks”. Tie ir mani sākotnējie minējumi no tālienes. Jūs varētu pārbaudīt stiepļu teoriju, noņemot zaļo stat stiepli no vadības paneļa pie krāsns, un pēc tam ļaujiet krāsnim darboties vēl vienu ciklu un pārbaudīt, vai tā izslēdzas. Tas vismaz jums pateiks, vai problēma ir stieples / termostata vai krāsns pusē. Ja tas izslēdzas, tas atrodas stat / stieples pusē. Ja nē, problēma ir krāsnī.

Jautājums: Mana gāzes krāsns ieslēdzas 4 ° zem termostata iestatītās temperatūras. Vai tas ir termostata jautājums?

Atbilde: Ja tas vienmēr ir bijis šādā veidā, tad tas var būt tikai vecs statuss un vairs nav ļoti precīzs, tāpēc, iespējams, vēlēsities to nomainīt. Ja tā nav, un jūsu statistika ir jaunāka, tad tā ir kļūdaina, un viņiem jums vajadzētu dot jaunu.

Jautājums: Man ir Payne krāsns, un induktora motors un ventilators pastāvīgi darbojas. Mans karstums netiks ieslēgts, un vadītais kods norāda, ka spiediena slēdzis nav atvērts. Esmu pārbaudījis šļūteni, un tur nav problēmu. Vai man vajadzētu mēģināt nomainīt krāsns spiediena slēdzi?

Atbilde: Izklausās, ka, iespējams, slēdzis ir slikts, tāpēc jā. Tā kā tas ir lēti, es vismaz to izmēģinātu, un, ja tas nedarbojas, varbūt piezvaniet tehniskajam darbiniekam, bet, ja tas izdosies, tas var ietaupīt daudz naudas.

Jautājums: Mana Goodman 96% divpakāpju krāsns sāk darboties agri no rīta, kad termostats pirmo reizi prasa siltumu. Pēc vairāku minūšu karsēšanas krāsns atslēdzas, it kā termostata izsaukums būtu apmierināts. Tomēr sistēma nekavējoties atsāk sākuma ciklu un turpina sildīt vēl vairākas minūtes, līdz termostata izsaukums ir patiesi apmierināts. Vai tas šķiet augsta slēdža jautājums?

Atbilde: Es tā nedomāju. Es domāju, ka tā ir jūsu krāsns pāreja no 1. uz 2. posmu. Varbūt tā ir normāla funkcija un nemaz nav problēma.

Jautājums: Kāpēc mana krāsns darbojas pareizi tikai tad, ja apakšējās iegrimes durvis ir izslēgtas?

Atbilde: Vairāk nekā iespējams, tas nozīmē, ka iekārta nesaņem pietiekami daudz atgriešanās gaisa. Varbūt kanāli ir pārāk mazi vai vienība ir pārāk liela. (Tas nozīmē, ka ventilators ir pārāk spēcīgs kanālam) Varbūt ventilatoru var iestatīt lēnāk, taču jums jābūt uzmanīgam, ka tas nav pārāk lēns, vai arī jūs varat tirgot vienu problēmu pret citu, un jums būs jākonsultējas ar tehniku protams. Diemžēl šim lēmumam ir tālu līdz daudz, ko es šeit paskaidroju.

Jautājums: Kas pūtēju darbinātu režīmā, bet ne automātiskajā režīmā?

Atbilde: Ventilators ieslēgsies tikai tad, ja būs aicinājums uz apkuri / dzesēšanu režīmā “auto”. Ventilatora ieslēgšanas režīms pats ieslēdz ventilatoru, bet joprojām ļauj siltumam un vēsumam darboties kā parasti. Ja tas nedarbojas siltuma / vēsuma "automātiskajā" režīmā, dažiem, manuprāt, ir jābūt nepareizam statistikā vai dēlī.

Jautājums: Man ir Goodman krāsns, un tā darbojas labi, kamēr es termostatu turu 80 un vairāk, bet, ja es pagriezīšu to zemāk par 80, gāzes vārsts neatvērsies. Vai jūs varat man palīdzēt?

Atbilde: Izklausās, ka stat varētu būt jūsu problēma. Es nevaru iedomāties nevienu citu iemeslu, kas varētu notikt.

Jautājums: Krāsns ieslēdzas. Mājas temperatūra sasniedz vēlamo temperatūru. Tad degļi izslēdzas, bet pūtējs turpina pūst. Parasti pūtējs izslēdzas pēc aptuveni 100 sekundēm, bet laiku pa laikam turpina pūst, un vienīgais veids, kā izslēgt, ir drošinātāju kārba. Vai tas var būt slēdzis virs degļiem vai slēdzis, kas atrodas pie pūtēja?

Atbilde: Pūtējs to parasti dara tikai tad, ja ir kļūda. Ja pēdējā laikā nav veiktas nekādas kļūdas un izmaiņas nav veiktas, iespējams, dēlis ir slikts, un pūtēja nepārtraukta darbība ir īss. Nevaru to droši pateikt, bet es to skatītos.

Jautājums: Cik gadus ilgst ierobežojošie slēdži un termopāri krāsnī?

Atbilde: Jebkura veida mehānisko daļu kalpošanas laiks ievērojami atšķirsies no daudzām dažādām lietām. Es varu tikai teikt, ka tiem ir paredzēts garantijas laiks. Šādi uzņēmumi izdomā lielāko daļu savu garantiju nosacījumu, pamatojoties uz paredzamo darbības laiku. Ja jūs zināt, cik ilga ir jūsu detaļu garantija, jums ir diezgan laba ideja par to paredzamo mūžu. Tas viss nozīmē, ka, ja detaļa nepārtraukti nedarbojas, vai nu ražotājam ir defekts, vai arī ir kāds iemesls, kāpēc detaļa joprojām neizdodas, un jums tas būs jānoskaidro. Parasti tas ir pēdējais.

Jautājums: Man ir apmēram gadu veca Goodman krāsns. Tas kādu laiku darbojas, pūšot karstu gaisu, un mēģina sasniegt termostatā iestatīto temperatūru. Pēc kāda laika mēģinot sasniegt mērķi, tas tiek pārtraukts. Skatoties uz krāsni, es redzu, kā četras reizes mirgo sarkanā gaisma. Vai filtra nomaiņa un nepareiza novietošana plūsmas virzienā varētu izraisīt šo problēmu?

Atbilde: Nē, es neredzu, ka filtrs būtu atpakaļ, kas izraisītu šo problēmu. Es neesmu pārliecināts, kas ir, bet, kas, manuprāt, nav.

Jautājums: Kas man ar krāsni nav kārtībā, kad tā aizdegas un pēc tam izslēdzas?

Atbilde: Ja tas ir patiešām ātri, tad varbūt tas ir liesmas sensors.

Jautājums: Mana krāsns parasti nesākas pati. Es varu ieslēgt un izslēgt slēdzi krāsns sānos, un tad tas sāks darboties, bet citādi tas reti sāksies. Es nomainīju termostatu, taču problēma paliek. Induktora motors ir arī diezgan jauns. Gaisma nemirgo. Kas tas varētu būt?

Atbilde: Lai gan man šeit nav pietiekami daudz informācijas, lai ieteiktu izšķirtspēju, es neturpinātu darīt to, ko jūs darāt, nepievēršot tam tehnoloģiju. Tas, iespējams, varētu būt nedrošs un, ja ilgāk gaidāt, jums izmaksās vairāk naudas, nemaz nerunājot par neērtībām.

Jautājums: Vai 80 grādi ir pārāk karsti, lai darbinātu jūsu gāzes krāsni?

Atbilde: Manuprāt, jā. Tas to var izdarīt, taču, iespējams, tas maksās nelielu laimi.

Jautājums: Kāds būtu galvenais iemesls tam, ka manas krāsns aizdedzi pēdējo četru mēnešu laikā vajadzēja nomainīt trīs reizes?

Atbilde: Es domāju, ka jums vai nu ir nepareiza daļa, vai arī nepareizs spriegums nāk no tāfeles. Dažādiem aizdedzēm ir nepieciešams atšķirīgs spriegums ... parasti 80 vai 120 V, un, ja detaļa ir pareiza, bet spriegums nav, tad tas to var izraisīt. Pretējā gadījumā, ja pieskaraties aizdedzes virsmai tur, kur tā spīd, tas var sabojāt arī jūsu jaunos aizdedzinātājus. Eļļas no mūsu ādas var izraisīt HSI izdegšanu.

Jautājums: Es no savas krāsns saņemu 4 mirgojošas gaismas, kas nozīmē atvērtu gala slēdzi. Šodien ir -40c, tāpēc es domāju, vai tas pārkarst un izslēdzas tikai tāpēc, ka tam ir grūti sekot līdzi? Vai arī pastāv kāda aktuāla problēma?

Atbilde: Pārbaudiet, vai filtrā nav gaisa plūsmas, lai tas būtu vēss. Ja iespējams, pārbaudiet gaisa kondicionētāja spoli, lai pārliecinātos, vai tā ir pieslēgta vai tīra, lai nodrošinātu labu gaisa plūsmu. Šīs lietas ir bez maksas. Ja nē, jums var būt tikai slikts limita slēdzis.

Jautājums: Mana gaisma mirgo deviņas reizes, un mans kods liecina, ka tas ir aizdedzinātājs. Es divas reizes esmu nomainījis aizdedzi, un joprojām nav siltuma! Vai kāda palīdzība būtu ļoti pateicīga?

Atbilde: Atvainojiet, taču šie kodi katram zīmolam nav vienādi, un es tos visus nezinu. Kods nozīmē tikai to, ka neizdevās aizdegties, nevis to, ka aizdedzinātājs ir slikts. (Instalēšanas laikā jūs nevarat pieskarties aizdedzes aizdedzes daļai, vai arī tā saīsinās jauno, tāpēc, ja tā bija problēma, un jūs pieskārāties šai tās daļai, tas ir iespējams, bet, ja tas spīd, tad tam nevajadzētu būt Tas nozīmē, ka ir daudz iemeslu, kāpēc krāsns neļaus sevi uzliesmot, un man būtu vajadzīga vairāk informācijas par to, kas notiek līdz šim brīdim, vai arī jāveic elektriskās pārbaudes, lai precīzi noteiktu problēmu.

Jautājums: Mana krāsns iedegsies un darbosies, bet kad tā izslēdzas, vienmēr nodziest kontrollampiņa, kā es varu to novērst?

Atbilde: Izklausās, ka jums vajag termopāri.

Jautājums: Manas ārējās krāsns izplūdes gāzes vāji smaržo pēc dabasgāzes, bet iekšā nav nekā. Vai tas ir normāli?

Atbilde: Es nekad neesmu par to dzirdējis vai uzskrējis un nespēju iedomāties, kā tas būtu. Tas nozīmē, ka, ja jūs patiešām darāt, tad es to pārbaudītu. Jūs nekad nevēlaties smaržot gāzi.

Jautājums: Ko tas nozīmē, ja balts pūtēja motora vads, kas piestiprināts pie melna vada, kas savienojas ar ventilatora ierobežojošo vadu, pieskaras pūtēja korpusam un tas sāk darboties? Tas ir īss motors, kas nozīmē nomainīt labi? Pūtējs neieslēdzas citādi, un pārtraucējs turpina paklupt.

Atbilde: Tas izklausās pēc īsa, jā.

Jautājums: Kāpēc iedegas signāllampiņa, kad mana krāsns sāk darboties?

Atbilde: Tā varētu būt vāja liesma, tāpēc jebkura veida gaisa pretplūsma to varētu izdzēst. Varbūt tas tomēr ir pārtraukts pilots. Es nezinu par pārāk daudziem šādiem uzņēmumiem. Varētu būt slikta termopāra. Varbūt slikts siltummainis. Es tiešām nevaru droši pateikt, ja neesmu tur klāt un neizpildītu dažus testus.

Jautājums: Ko nozīmē "atvērts spiediena slēdzis, darbinot degšanas gaisa induktoru"?

Atbilde: Tas nozīmē, ka elektriskais savienojums, kurā spiediena slēdzim vajadzētu "aizvērt", nebija, un tas, ka tas bija "atvērts", neļaus elektrībai pāriet uz nākamo soli, tāpēc vai nu slēdzis ir slikts, vai arī kaut kas novērš pietiekamu sūkšanu, lai to izdarītu "aizvērt". Var būt slikts induktors vai bloķēts skurstenis, bet parasti tas ir slēdzis. Tas būtu pirmais, ko es pārbaudītu.

Jautājums: Man ir apmēram 4 gadus veca ruud krāsns. Nesen tas sāk īsu ciklu. Esmu visu pārbaudījis un pat nomainījis filtru, bet tas joprojām dara to pašu. Esmu varējis novilkt durvis, un tās darbojas labi, bet, ieliekot durvis atpakaļ, tās atkal saīsinās. Kāda varētu būt problēma?

Atbilde: Tas varētu būt netīrs un vēlas vairāk gaisa, taču tas varētu būt arī krasi zems temps, liekot vienībai darboties vairāk, lai tiktu līdzi. Manējais dara.

Jautājums: Man ir Goodman piespiedu gaisa krāsns, kas ir apmēram 13 gadus veca. Es nomainīju spiediena slēdzi dažus gadus atpakaļ un arī ventilatoru nomainīju apmēram pirms gada. Pašlaik man ir problēmas ar siltuma iegūšanu. Krāsns darbosies, bet dažreiz tā nepūš karstu gaisu. Kad tas notiek, izklausās, ka degļi ieslēdzas un izslēdzas. Es jau nomainīju termostatu, bet tas nedarbojās. Kādas idejas?

Atbilde: Ja degļi sāk darboties un gandrīz nekavējoties ieslēdzas liesmas sensors, bet pēc tam es nevaru ieteikt, pamatojoties uz sniegto informāciju.

Jautājums: Kāpēc ārējais ventilators neieslēdz manu krāsni? Tas ir iestrēdzis.

Atbilde: Ja jūsu ventilators ir “iestrēdzis”, motors, visticamāk, ir bloķējies un būs jāmaina.

Jautājums: Kādai temperatūrai vajadzētu būt gaisam, kas iziet no siltuma apmaiņas? Vai 113 grādi ir pareizi, vai tam vajadzētu būt no 120 līdz 125 grādiem?

Atbilde: Ventilatora ierobežojuma slēdzim vajadzētu pateikt, kādā diapazonā vajadzētu darboties temperatūrai. Uz tā var būt apzīmogoti EX - 130–160 grādi.

Jautājums: Kamēr krāsns atrodas garā karstuma ciklā (~ 30 minūtes), es dzirdēšu, kā induktora motors uz 1 sekundi tiek izslēgts, un pēc tam tas tiek restartēts un turpina darboties. Šī induktora 1 sekundes izslēgšanās var notikt 3 vai 4 reizes 30 minūšu siltuma cikla laikā. Šim 1 sekundes periodam izslēdzas tikai induktora motors. Krāsns pūtējs turpina darboties. Vai IDM ir jāmaina vai, iespējams, apaļais manuālais Honeywell termostats? 14 gadus veca Tempstar krāsns.

Atbilde: Statam ar to nebūtu nekāda sakara. Vai jums ir mainīga ātruma induktors? Varbūt mainīt tā ātrumu? Ja nē, tad tam vajadzētu darboties visu ciklu, jo, ja tas apstājas, spiediena slēdzis tiks atvērts un izslēgts, un, ja jums tas tā ir, priecājieties, ka tas ir tikai sekunde, vai arī jums nebūtu siltuma. Iespējams, vēlēsities to pārbaudīt, pirms tā ir steidzama.

Jautājums: Mana gāzes krāsns pagriežas o, darbojas dažas minūtes un pēc tam izslēdzas. Esmu nomainījis drošinātāju un nomainījis arī motoru. Kas tas vēl varētu būt?

Atbilde: Labi, es neaizstātu lietas, ja vien nezinātu, ka tās ir sliktas naudas taupīšanas nolūkos. Es nevaru pateikt, balstoties uz šeit sniegto informāciju, taču, lai noskaidrotu, kurā cikla brīdī tā apstājas, tas palīdzētu. Varbūt ķēdes pārbaude būtu vislabākā, ja zinātu, ko meklējat. Ja nē, jums vajadzētu piezvanīt speciālistam un ļaut viņiem diagnosticēt.

Jautājums: Mana aukstā gaisa ieplūdes caurule pūta karstu gaisu pēc induktora ventilatora izslēgšanas, vai tas ir normāli?

Atbilde: Nē. Ieplūdei nekad nevajadzētu izpūst gaisu.

Jautājums: Ja induktora ventilators darbojas, bet, iespējams, nolietojas, vai tas var izraisīt spiediena slēdža nepareizu darbību?

Atbilde: Varētu, jā. Tas neizraisītu pietiekami daudz vakuuma, lai iedarbinātu slēdzi.

Jautājums: Mana 1979. gada Rheem krāsns manā augšstāva sildītāja skapī labi darbojas ar 1/2 zilu 1/2 dzeltenīgu pilota liesmu. Durvju iekšpusē, kur tas atrodas, ir ļoti karsts pieskāriens, un arī skapja iekšpuse ir uzkarsusi! Es baidos izmantot savu sildītāju, vai tas varētu būt ugunsgrēks? Kas varētu izraisīt karstās durvis un siltumu skapī? Kas jāpārbauda?

Atbilde: Es domāju, ka tas ir tik karsts, jo tas, visticamāk, ir dabiskas iegrimes vienība un atrodas ierobežotā telpā. Redzot, ka tas ir gandrīz 40 gadus vecs, ja jūs varat, es apsvērtu iespēju nomainīt budžetu aizstājējam un noteikti ieguldītu dūmu / CO detektorā.

Jautājums: Es uzstādīju savu jauno eļļas krāsni Patriot 80. Palaida to un viss izdevās! Deglis ieslēdzās, skrēja uz savu ciklu un izslēdzās. Bet tad es pamanīju, ka siltuma kustības pūtējs neiedarbojās. Kas man jāpārbauda?

Atbilde: Ņemot vērā, ka iekārta ir jauna, vispirms pārbaudīšu, vai nav izveidots savienojums. No turienes jums vienkārši ir jāpārbauda ķēdes un jāskatās, kur ir sadalījums, un pēc tam jānosaka, kāpēc. Ir dažas pārāk daudz iespēju uzskaitīt, pamatojoties uz sniegto informāciju.

Jautājums: Sveiki. Man ir divus gadus veca RUUD gāzes krāsns. Tas darbojas tieši 8 minūtes, pēc tam viss tiek izslēgts un tiek restartēts pēc 30 sekundēm. Šis cikls atkārtojas, līdz tiek sasniegta vēlamā temperatūra. Es apeju termostatu, un notiek tas pats. Kādi ieteikumi?

Atbilde: Dažreiz divpakāpju krāsns to darīs starp posmiem, bet, ja tas konsekventi notiek visā ciklā, un jūs esat pārcēlis statistiku, vispirms man būtu aizdomas par hi limitu. Pārbaudiet filtru un, ja vienība nav notīrīta ... iespējams, pārāk daudz gaisa neizkļūst no plēnuma. Tas ir tikai minējums no tālienes un tas, ko es pārbaudītu tālāk, ja es tur būtu.

Jautājums: Mana krāsns man uzrāda kļūdu, kurā teikts “pārbaudīt aizdedzi vai zemi”. Viss darbojas pareizi, līdz pūtējs iedarbojas. Tajā brīdī degļi izslēdzas, un pūtējs darbojas apmēram minūti. Tad tas izslēdzas, un process sākas no jauna. Vai to es varu uzrunāt?

Atbilde: Diemžēl, lai gan tas var būt kaut kas vienkāršs, ko jūs, iespējams, varēsiet novērst, es nevaru palīdzēt precīzi noteikt problēmu, neveicot testus. Mēģiniet atiestatīt slēdzi un pārbaudiet filtru. Skatiet, vai notiek kaut kas tāds, kas šķiet parasts, bet citādi, iespējams, būs jāveic elektriskie testi. Atvainojiet.

Jautājums: KĀPĒC elektriskā krāsns iedarbina slēdzi, bet ne gaisa kondicionētāju?

Atbilde: Šīs divas vienības atrodas atsevišķās ķēdēs (vai tām vajadzētu būt), tāpēc tas nav nekas neparasts.

Jautājums: Vai, izmantojot sildītāju, jādarbojas ārējam gaisa kondicionēšanas ierīces ventilatoram?

Atbilde: Tas būtu siltumsūknis un ne vienmēr. Ventilators atdzesē kompresoru ... šobrīd lielākajai daļai problēmu nav, tāpēc tas nedarbosies, ja tas nav vajadzīgs.

Jautājums: Manai krāsnij ir 10 gadu, un to pašu uzņēmums divas reizes gadā tīra un pārbauda. Pirms mēneša iznāca fella un iztīrīja to, kā neviens cits nekad nav darījis. Viņam bija gabali visā vietā! Tagad filtri ir netīri ik pēc divām nedēļām ... vai ir kāda ideja, kāpēc? Melnīga krāsa.

Atbilde: Nu, ja pūtējs pirms tam nebūtu ticis izņemts un iztīrīts, tas varētu darboties labāk, tādējādi ievelkot vairāk putekļu.

Jautājums: Kā es varu salabot krāsni, kad tā ir ieslēgta un kad tā ir izslēgta?

Atbilde: Ja tas ir eļļas konservu cauruļvadu darbs (kas parasti ir šāda veida skaņa ... ar ventilatora spiedienu un spiedienu), jums jāatrod vājais punkts un tas jāpastiprina.

Jautājums: kāpēc pūtējs darbojas visu laiku un nekad neizslēdzas?

Atbilde: Ja tas darbojas "visu laiku", tad vai nu jūsu ventilatora slēdzis ir iestatīts uz "ventilators", nevis "auto", vai arī ir īssavienojums vai nu zemsprieguma elektroinstalācijā, stat vai pie tāfeles. Jūs varētu atvienot zemo spriegumu no tāfeles, lai redzētu, vai tas apstājas. Tas jums pateiks, vai problēma ir tāfele (ja tā turpina darboties) vai arī tā ir elektroinstalācijā un stat. Pēc tam tur atkal pievienojiet vadus un atvienojiet stat. Ja ventilators turpina darboties, tad stat ir kārtībā, un problēma ir stieple. Zaļais vads kontrolē ventilatoru. Tātad, sarkanā krāsā pieskaroties, ventilators darbosies nepārtraukti. Izmēģiniet to tikai tad, ja esat pārliecināts, ka zināt, ko darāt.

Jautājums: Es instalēju jaunu iegrimes induktoru (izplūdes pūtēju), kuram bija četri gala slēdži, uz kuriem ir četri dažādu krāsu punkti (balti, dzelteni, sarkani un zili). Manā krāsnī ir tikai divi robežslēdži, augšējais robežas slēdzis ir ar zilu punktu un apakšējais ar dzeltenu punktotu. Vai es pareizi lietoju jauno dzeltenā punktētā gala slēdzi, jo es aizstāju tikai pašreizējo dzeltenā punktētā apakšējā slēdža slēdzi?

Atbilde: Izklausās, ka jums ir "komplekts", kuru var izmantot dažādās vienībās, tāpēc es teiktu, ka jā, jums to vajadzētu darīt, lai gan es, iespējams, izdarītu abus ierobežojumus, bet vismaz saglabātu tos, kas iet jūsu ierīcē kā rezerves daļas.

Jautājums: Mana krāsns darbojas labi. Tas tiek izvests no mājas priekšpuses. Kāpēc ārā ir tik dīvaina smaka tikai tad, kad krāsns ieslēdzas?

Atbilde: Vienīgās nepatīkamās smakas (līdzīgas sapuvušām olām), par kurām es zinu, ir izraisījušas sliktu siltummaini. Es nesaku noteikti, ka tas esat jūs, jo es nezinu, ko jūs smaržojat, bet parasti no šīm ventilācijas atverēm nav sliktas smakas.

Jautājums: Induktora motors neiedarbojas vai veic pusi pagrieziena, kad no termostata tiek aicināts uz siltumu. Motors griežas diezgan labi, kad griežas ar roku. Vai manas krāsns induktora motors ir bojāts vai kaut kas cits, piemēram, spiediena slēdzis, nedarbojas? Gaisma dod man kodu 31.

Atbilde: Iespējams, ka jūsu induktorā ir kondensators, kas ir slikts. Ne visām vienībām tādas ir, bet dažām ir. Ja nē, tad varbūt dēlis nesūta enerģiju induktoram. Jums jāpārbauda spriegums, lai pārliecinātos, ka tas notiek, un, ja iespējams, motors joprojām ir slikts, lai arī griežas brīvi.

Jautājums: Krāsns darbojas un silda māju labi, bet māja ir sausa. Krāsns mitrinātājs darbojas, bet māja joprojām ir sausa? Ko es varu izmēģināt?

Atbilde: Vai esat palielinājis mitrinātāja radīto mitruma procentuālo daudzumu? Mitruma pievienošana ir vienīgais veids, kā novērst problēmu. Varbūt jūsu mitrinātājs nav pareizi izmērīts. Es vēlētos, lai es varētu pievienot kaut ko vairāk, bet, ja viss darbojas, patiesībā nav "labojumu".

Jautājums: Gandrīz katru rītu, kad pamostamies, un mūsu māja sasalst. Ejot uz mūsu krāsni, es redzu kļūdas kodus 10 un 61. Kāpēc mums pastāvīgi ir pūtēja kļūda? Krāsns ir pavisam jauna!

Atbilde: Lai gan es nevaru būt drošs, ka tas ir jūsu jautājums, bieži vien, ja kādam ir pastāvīgi pūtēja jautājumi, tas ir tāpēc, ka gaiss, kas nonāk krāsnī, ir nepietiekams. Tas var būt netīrs filtrs, mazizmēra kanāls vai nepietiekams atgriešanās gaisa reģistru skaits. Tas ir īpaši bieži, uzstādot jaunu ierīci vecākam mājas kanālam, un kanāls nav pareizi pārtaisīts.

Jautājums: Mans gāzes krāsns modelis nugm100ehb1 ņem degšanas gaisu no mājas iekšpuses, vai tas ir pareizi vai pareizi?

Atbilde: Jā, ja vien ir pietiekami daudz brīvas gaisa telpas. Instalēšanas rokasgrāmatā ir diagramma, kas jums pateiks, cik daudz kvadrātpēdu jums vajadzētu būt. Turklāt es neesmu pārliecināts, vai tas attiecas uz jūsu modeli, bet daži saka, ka tas saīsinās ierīces garantiju. Lai to uzzinātu, ieteicams apskatīt rokasgrāmatas un garantijas detaļas.

Jautājums: Mūsu krāsns darbojas tikai tad, kad mēs atvienojam gaisa ieplūdes cauruli no tās savienojuma pie krāsns. Mēs esam nodrošinājuši, ka gaisa ieplūdes caurule ir tīra. Krāsns ir deviņdesmit procentu efektīva krāsns. Kādi ieteikumi?

Atbilde: Iespējams, ka gaisa ieplūde ir pārāk maza nobrauktajam attālumam. Jums vajadzētu iepazīties ar instalēšanas rokasgrāmatu, lai uzzinātu, kāds ir ieteicamais izmēra lielums atkarībā no attāluma.

Jautājums: Kāpēc mana krāsns gāzes vārsta spieķis visu laiku ir atvērts?

Atbilde: Es uzdrošinos teikt, vai nu tas ir bojāts, un tas ir jāaizstāj, vai arī tas ir nepareizi savienots un saņem pastāvīgu jaudu, nevis atveras pēc komandas.

Jautājums: Manam termostātam ir taimeris (atvaļinājums / atgriešanās utt.), Tāpēc mana krāsns pirmo reizi tiek prasīta līdz temperatūrai, bet pēc tam tiks izslēgta līdz nākamajam intervālam. Kas, jūsuprāt, tas ir?

Atbilde: Tirgū ir simtiem termostatu, tāpēc es neko daudz nevaru pateikt, kā izlasīt rokasgrāmatu un vēlreiz pārbaudīt programmēšanu. Izklausās, ka, iespējams, kaut kas ir nepareizi ieprogrammēts. Diemžēl viņi visi programmē atšķirīgi, tāpēc es negribētu uzminēt.

© 2012 Dens Rīds

Suzie N 2020. gada 13. martā:

Man ir 6 gadus veca Goodman propāna krāsns, un nesen krāsns induktoram nācās pūst gaisu 4 līdz 5 reizes, pirms siltums sāk darboties. Apkalpotājs iznāca un visu iztīrīja, un, protams, tas bija lieliski, kamēr viņš bija šeit, tomēr vēlāk tas atkal sāka pūst skaņas. Viņš domā, ka tas ir induktors, bet es domāju, ka pūtēja induktora uzdevums bija izpūst gaisu. Vai jums ir kādas idejas

Merlina M 2019. gada 6. oktobrī:

Sveiks, Dan,

Fantastisks raksts, paldies.

Mums ir veca Heil krāsns, kuru drīz vajadzēs nomainīt. Līdz tam mēs cenšamies klibot (mazpilsēta un būvuzņēmēji ir ļoti aizņemti)

Mūsu krāsns nokļūst starp 7. un 8. soli, bet īsiem cikliem. After the system warms up (flame burns for ~60 sec) the blower comes on but then the system starts to short cycle. Flame is on for about 2sec then off, one 2sec off and so on. Heat is delivered to the vents but clearly this is not right.

I have done the basic, check filter, change thermostat batteries, looks on roof to ensure eventing. At first I thought flame sensor but tow problems with that,

One, if that was the issue why would the furnace warm up. My thought is a bad sensor would prevent this. And two, for the life of me I cannot see a flame sensor on this unit.

Kādi ieteikumi?

Camster on March 13, 2019:

Hi Dan. So yesterday a furnace technician came to inspect my 23 year old Lennox High Efficiency Gas furnace. He said that the temperature in one of the ducts registered 68 degrees and if it reaches 70 the furnace will shut down. He said I probably need a new furnace. What is he talking about please?

[email protected] on March 08, 2019:

Every time we cut our furnace on into the old one it's one of the fan blowers fucking ancient and now it smells and it's smoking so when we cut it off and then we try to cut it back on the next day it just doesn't even turn on what could it be it was really dusty and stuff my life but another filter for it and it's just not working we cut the switches back on through the fuse box and it doesn't cut on and it's getting cold man what do I do what could it be

connie 2019. gada 1. janvārī:

I have a new York furnace in my garage. I noticed that I feel warm air coming out of the furnace box in garage, while it is dispenseing warm air into the living space.

Dens Rīds (autors) on November 21, 2018:

Joe689 - So here's a theory. The old stat was perhaps inaccurate thus maybe the furnace wasn't heating up as much. No perhaps it's running longer thus increasing the temperature in the duct. As it heats up, the duct may expand and as the heat shuts off but the fan is still running and the temperature dropping the duct contracts and causes a "thump" or oil canning sound. I can't really see any other way a thermostat could cause this to start happening other than pure coincidence.

Joe689 on November 19, 2018:

Hi Dan, thank you for the detailed run down. Very easy to follow and intuitive. Thanks for making a complex subject a little easier.

I have a Luxaire gas furnace. I just installed a new thermostat, and started to observe some different behavior. When the thermostat reaches its temp, I hear the "clicks", and then right after the furnace make a thump, deep enough to hear through the floor, and then one more thump almost right after. The fans continues to run for a minute, and turns off. This did not happen with old thermostat. The "thumps" also does not happen all the time. I try to recreate it by toggle the temp up and down but can not get it to repeat. Only when it has been on for some time, does this thump upon signal to turn off occur. And it does not happen all the time. By the way, this is for heat. What could this be? I know it is not the fan because the fan does not turn off right away. It is right might the thermostat clicks.

It never happened with old thermostat. I am about 99% sure I wired it correctly. All my wires were labeled, and I also wrote down what lettered slots they were going in on the former thermostat. With that, it was pretty much 1:1 with the new thermostat.

Thanks in advance

Dens Rīds (autors) on November 15, 2018:

Ray - While I can't be sure what the issue you're having is I can say that typically a unit that runs until there is a failure will automatically kick on the blower as a default safety feature but it should shut off within 5 minutes or so after that. If you're having a limit issue, this could be why you're having problems. Perhaps, since the part is cheap and easy to change, try replacing it and see if that doesn't resolve the issue.

Ray Brewer on November 15, 2018:

I have a furnace that if it stays on for a long period of time will trip the limit switch and blow cold air and the only way to shut it off is switch the breaker off. I have a new filter and all my vents are open. Not sure what else to check?

Dens Rīds (autors) 2018. gada 29. oktobrī:

Ryan - There are a few things that could be going on and it would probably be best to get an HVAC technician out there to look at it. Gas isn't anything to mess with and hopefully not but you could have a heat exchanger issue and that would definitely require a tech to repair. Good news would be that you likely still have a warranty on the exchanger if it is your problem. (Not the labor to install it but the part itself.)

Casey Rohman on October 28, 2018:

Thank you very much for your reply, Mr. Robbins. My post here didn't appear when I checked back after posting, thus my late response. The breaker is the proper size, and no other electrical problems are appearing in the house.

However, your advice regarding an electrical problem was correct. I think that even though I was careful to reconnect the new control panel properly, it seems likely that at least one of the connections was a bit loose. After I went through and rechecked them all as well as other electrical connections in the furnace, the problem disappeared and the furnace has been functioning properly since. Your patience and willingness to help are much appreciated!

Ryan Jewell on October 26, 2018:

I have aTrane 2 stage furnace. It makes it to around item 7 in your start up list. The furnace will be lit for about 15-20 seconds and then go out... I can hear a waffling whistle noise and see fluttering in the flame at the exit of the gas tubes like it has too much air or not enough gas flowing. And then the middle to further away from ignitor gas lines blow out and it cuts gas to the unit to shut off. Any thoughts on what wrong?

Dens Rīds (autors) on October 26, 2018:

You're welcome Brian. Glad I could help some. Vislabākos novēlējumus!

Dens Rīds (autors) on October 26, 2018:

Tom - I'm sorry no. There isn't enough here for me to offer sound advice. Perhaps the limit? Those are a common failure in older furnaces.

Brian S. Pollack on October 25, 2018:

Hi Dan,

Thanks for the input. It is the pressure switch. I can now return the control panel I ordered and had someone else install the pressure switch. Next time i'll know. thanks for your expertise!

Toms on October 25, 2018:

I have a old furnace it’s cal a Stewart Warner . It about 40 years old. I just had the thermal coupling replace and it was working fine then it warm up outside so I turn it off. Then when I needed heat again it wouldn’t come on. I can hear the click in the thermostat To on the furnace but nothing any idea?

Dens Rīds (autors) 2018. gada 23. oktobrī:

Don - This sounds more like a pressure switch problem to me. Perhaps check out my article on that and see if it helps.

Dens Rīds (autors) 2018. gada 23. oktobrī:

Brian - I would be more inclined to think it's the flame sensor or pressure switch. If the sensor is dirty or pressure switch is weak, it could be giving a false failure that can happen within split seconds causing the valve to click open and closed but so fast that the flames don't actually go out. This is my thought from a far. Perhaps check them and see.

Dens Rīds (autors) 2018. gada 23. oktobrī:

Casey - When there are multiple part failures in a row like this I always consider the incoming power and circuit. Is the breaker sized properly? Is the furnace on it's own dedicated breaker? Are there any other "occurrences" in the home with other appliances or lights? I wish I had an easy answer here but testing will definitely be required to definitively pinpoint the issue.

don murray on October 20, 2018:

Hi Dan, I have an older carrier furnace, light is on constantly, and no blinking noticed. Inducer spins, I hear the blower sound, igniter glows hot, then everything shuts down.

I just replaced the gas valve, and now the same thing is happening. Kādas idejas? could the gas valve I just put in be bad ? The gas is turned on to the furnace, lol...

Brian Pollack on October 20, 2018:

I am trying to figure out what going on with my Trane XE80. It can be either the limit switch, control panel, or gas valve that is clicking. The furnace runs, no problems with the start. It remains on and about ten minutes into blowing hot air it will click about 5-10x. The flames will flicker on and off with each click. The furnace is still running, the flames come back continually and the clicking goes away.

I have already checked the thermistor. Any thoughts?

Dens Rīds (autors) 2018. gada 18. oktobrī:

While your message isn't clear to me I can say that changing the filter will help keep temps down but has nothing to do with the pressure switch. The problem may be the pressure switch however the 2 are not related. Perhaps check out this article and see if it helps...https://dengarden.com/appliances/Everything-You-Ne...

Reed Wickstrom 2018. gada 17. oktobrī:

I have a Heil 2 stage filter and it does nothing when thermostat calls for heat; however, if I unplug the limit switch the inducer motor starts and then shuts off around 30 seconds later after I reconnect it. FYI, I checked the furnace filter and it was dirty. I am thinking that it overheated. Do you have any suggestions.

Dens Rīds (autors) on October 11, 2018:

Call the company who installed it and ask them to check it out.

Carol miller on October 11, 2018:

I have a 2 month old heater/air con. Installed and it gets very very hot to touch. What should i do?

Dens Rīds (autors) on May 16, 2018:

Craigh S - I can't be sure without testing. Maybe the board is bad? Are you sure it's the rollout switch and not the temperature sensor on the blower housing?

Craigh S 2018. gada 14. maijā:

Why would rollout switch error show when it a/c is used but not when heat is used?

Dens Rīds (autors) on May 01, 2018:

Derek - I really can't think off why these two would be running simultaneously because of your cutting concrete unless you got water on the board and shorted something out. I could maybe understand just the blower but not along with the inducer. And are you sure this is a result of your work or that you just happened to notice because you spent so much time down there?

dgrandstaff on May 01, 2018:

I was cutting concrete close to the furnace and there was a lot of dust, now the exhaust fan and the blower run at the same time nonstop.

Dee Kae on March 25, 2018:

Thank you for responding.

Dens Rīds (autors) on March 25, 2018:

Well Dee, Like other mechanical working things, they sometimes just do something weird and turning off and on the stat can trigger a new call and voila, it works. I wish I could offer a better explanation but it does happen. My furnace will sometimes shutdown on a real cold night because I believe the "heavy" cold air along with a right wind direction overcomes the pressure switch/inducer and can trigger a lock out. Wind stops, I reset the unit, voila...it works. It is very difficult when a cause can't be pinpointed. Next time the furnace shuts down see if you can catch the blinking red light code and maybe that would help.

Dee Kae on March 25, 2018:

I have a Tud-B series older Trane furnace. It is cleaned professionally every fall and last fall HVAC said it's still in great condition. On Feb. 22, March 3, March 6 and March 25, the furnace stopped working but started again when the thermostat was turned off and back on. I haven't called HVAC yet because it's happened late at night and on weekends so it has seemed to be better to try turning it off and on first. Once last summer the newer air conditioner stopped and they couldn't duplicate the problem because it started working when they got here and turned the thermostat back on. I have a newer electronic programmable thermostat. I've changed the batteries twice (display was still working), cleaned it (no visible dust) and tightened a loose anchor screw. What else could cause my problem besides a faulty thermostat? Turning the thermostat off and right back on has turned the furnace back on all four times. Thank you!

Dens Rīds (autors) on March 06, 2018:

I would say perhaps you have a slow close gas valve however if it keeps running or goes into lock out then I don't think that's it. It sounds like the valve itself maybe going bad. It's a "normally closed" valve and if the power is being lost in the valve then it will not hold it open and thus creating this intermittent issue. I can't swear to it without running tests but I would have it checked out because it will cause other components to wear out if it's constantly starting and stopping.

RandysPCs on March 06, 2018:

I have a Coleman furnace that acts like it's running out of gas sometimes. I have watched it and what happens is, the induction fan runs, ignitor glows, gas lights but then gradually the flame gets smaller and goes out. Then the gas valve clicks off and the cycle starts over, sometimes it will stay running sometimes it goes into lock out. Kādas idejas?

Dens Rīds (autors) on March 06, 2018:

Lowski - I'm nearly positive it's the flame sensor and is probably just a bit in need of a cleaning. You likely won't even be able to see dirt on it but it doesn't take much at all. I've written on how to do this so perhaps if you need some guidance you could check that out. Paldies, ka lasījāt.

lowski 2018. gada 5. martā:

Hi Dan,

I recently replaced the circuit board on my Ruud 80%. Apparently there was a bad relay, causing my inducer motor to constantly switch between hi and low, delaying the furnace from ever igniting. Since I switched out the board, it has worked fine, with the caveat that every once in awhile, when the inducer motor turns on and the pressure switch makes, I hear the gas ignite but then turn off right away; but the blower motor still comes on and blows cold air. Once the blower motor turns off, the inducer comes immediately on and the whole sequence starts again, but this time with the flame staying lit and working properly. Thoughts?

Dens Rīds (autors) 2018. gada 26. februārī:

Roger, There are a lot of possibilities based on the info you've provided. I would need more to offer any sound advice. Maybe igniter is bad? Maybe inducer/pressure switch is preventing it due to obstruction or part failure? Maybe board? I'm sorry but I can't help much at this time.

Roger 2018. gada 26. februārī:

furnace turns on but the igniters don't light up.

Dens Rīds (autors) on January 27, 2018:

I don't think it's either to be honest. Sounds more like an intermittent pressure switch issue. See my reply to John.

Dens Rīds (autors) on January 27, 2018:

Sounds similar to how a pressure switch will act sometimes. It's cheap and easy to fix so maybe give it a try if it's in the budget.

Jakobsdad 2018. gada 26. janvārī:

My furnace works perfectly for one or two cycles then it goes through the start up process but the igniter doesn't come on. The furnace continues through the whole start up process then blows regular air through the system. if I turn the thermostat to the off position and then back to heat it works perfectly for one or two cycles then repeats. do you think this is a thermostat issue or an igniter issue? the igniter works as it should after the manual power cycle from the thermostat.

Džons 2018. gada 26. janvārī:

My furnace works perfectly for one or two cycles then when the thermostat calls for heat the igniter doesn't light and it blows cold air only. I can turn the unit off then right back on and it works perfectly again until one or two more cycles then I have to repeat a powering down to get it to work

Kathleen8 2018. gada 26. janvārī:

You are probably right! hahahhaha I figure it there was a problem, it would have shown itself by now. Paldies!

Dens Rīds (autors) on January 25, 2018:

And though I hate to say it, that may be exactly why this is an issue for you. Furnaces aren't as quite when you have to sleep next to one as they are in a basement and is likely why the evenings seem worse...it's quieter, colder, and you're right there for it all.

Kathleen8 on January 25, 2018:

Honestly, I don't know about furnaces. It's a Carrier 59SC5A I believe.. I don't believe the manual says it's 2 stage. I thought the filter was dirty, so I changed it with a nice Filtrete filter and no sluggish noises upon the start of cycling. Then 3 weeks later, it started doing it again. I looked at the filter and it was dirty again. So, I jut put in a filter from ACE Hardware and the noise came back. It will only usually happen in the evening when it actually does happen.. You hear the switch and then it's this sluggish noise like it's having a bit of trouble getting going) from what I assume is the air draft inducer and then it starts blowing just fine. My brother thinks maybe it's just working harder? I can't believe I'm the only person with this issue..then again, I live in a tiny house and the furnace is right there next to my bedroom so I hear EVERYTHING.

Dens Rīds (autors) on January 25, 2018:

Kathleen8 - I can't really say much based on the information here but since it's condensing...is there a chance it's also a 2 stage unit??? If so, the gas output and blower speeds may vary by cycle and whether it's calling for the first or second stage.

Kathleen8 on January 25, 2018:

Hi, I have a Carrier Condensing gas furnace. Sometimes, when the furnace kicks on and starts it's cycle, it sounds sluggish before the blowing begins. Most times, you hear the click, the cycling starts and it starts blowing but it seems like since we are in the midst of winter and it's on all the time, it happens for a few cycles during the evening, but not all the time... Any ideas? Could there be dust stuck somewhere? Paldies!

Dens Rīds (autors) on January 16, 2018:

Unfortunately there are a too many possibilities for me to say anything certain. Maybe a fan limit? Intermittent pressure switch? Gas valve? Circuit board? Unless you just want to start throwing parts at it, you'd need a tech to troubleshoot the circuit.

Phyrfitr on January 16, 2018:

i have a york 90+ 100,000 btu single stage unit, the thermostat will call , the inducer motor will spin up the solid igniter will glow the gas valve will open and the furnace will cycle, for five minutes or so then the flame will go out but the inducer and blower motor will continue to run, the igniter will glow and the gas valve will start clicking constantly and the flame will ignite multiple times causing multiple fuel ignitions sometimes making a Poof sound, I sit and watch it thru the peep hole, this has been going on now for about A week, Any thoughts ?

Bill Fish on January 14, 2018:

Thanks for responding to my question. You said that my problem might be related to the flame sensor, with the limited info I gave ya. So I cleaned the flame sensor, which was very simple, and my furnace is working great again. I probably saved a couple hundred dollars by doing that myself. Thanks again.

Steve Stark on January 08, 2018:

I have a 14 yo Tempstar gas furnace. During a long heating cycle, the inducer motor will cut off for a second and then come back on. This happens maybe 3 or 4 times during the heating cycle. Does the IDM need replacement? Or, could the thermostat be faulty? (round manual Honeywell thermostat) Thanks

Dale 2018. gada 3. janvārī:

Have a 10 year old furnace, have it cleaned and checked twice a year. A month ago the fella took the thing apart like never before, put it back together and left. Now the filter is filthy after two weeks. That never happened before. Have any ideas what happened? Paldies. 1/3/18. [email protected]

Earl 2018. gada 3. janvārī:

My furnace will not stay running unless the door is off, why?

Dens Rīds (autors) 2017. gada 30. decembrī:

Angelo - It seems maybe the thermostat is the issue since the furnace will only turn on when the stat says to so perhaps it's not reading properly???

Dens Rīds (autors) 2017. gada 30. decembrī:

Jeff - I'm sorry but there isn't enough for me to offer much. Check your filter. Could be a high limit switch??? Not sure though.

Angelo 2017. gada 29. decembrī:

I have Lennox Meritt series that's 13 years old. It started to act weird yesterday. It will only turn the furnace on and maintain the house temperature if the thermostat is set at 73 and above. If I set the thermostat below 73, it will will not turn on the furnace.

Džefs on December 28, 2017:

I have a Coleman I replaced the pressure switch and the thermostat it is running a cycle at two set to 70 but any higher it will run as well then shut off and not fire in less I turn it back down to 70 and cut power and reset it

Dens Rīds (autors) 2017. gada 26. decembrī:

RK - It sounds like you either need a new motor and/or motor capacitor. I don't recommend using your hand. I suppose it may be getting bad voltage from the board as another possibility but you may want to call a tech.

RK 2017. gada 26. decembrī:

Hello, I have Carrier weathermaker 8000 gas furnance. Very often furnace would not start and I have to rotate the motor by hand and press the cover switch to start again.. If i leave it, it may start randomly after few hours on its own Any suggestions

Dens Rīds (autors) 2017. gada 17. decembrī:

Craig, Though I can't say for sure from here, I would first check the hi limit and is the coil for your a/c new too? If not, perhaps it is clogged and blocking air flow??? Is the new furnace fan perhaps more powerful? If so, your ducts may not be big enough on the return side...especially if you added an air cleaner. These are my suspects. Paldies, ka lasījāt.

Craig on December 15, 2017:

Have a Goodman furnace installed on 2016. I set the thermostat to 72 the furnace starts up. Runs for a while tries to make temperature but then cuts off and there is red light blinking 4 times. After a while when the temperature has dropped it kicks back in. I replaced the filter. The thermostat was recently replaced. I have checked the airflow outlet and inlet they don't have any objects. Would a leaking window sill or older windows result in this kind of behavior where the furnace cuts off? This is again a brand new furnace.

Dens Rīds (autors) 2017. gada 14. decembrī:

Greg, I'm not sure what advice to offer based on this info. You experienced some sort of failure that is apparently intermittent so when you reset the breaker it started over and apparently didn't have the same problem at that time. In short, something is happening to shut down the unit and you'd need to know at what point in the cycle the unit shut down and caused the unit to "lockout". Any failure that happens 3 times will put the furnace into "lockout" for a set period of time before it tries again. Sorry I can't be of much help based on this info.

Greg Staples on December 13, 2017:

Furnace stopped working the other day, wiggled wires, tripped breaker back and forth, after a bit it came on and worked through the night fine. Same thing happened again the next night. Replaced the breaker because there didn't seem to be any power going to the furnace. Furnace is working so far today but when it is running it seems to ossolate power now and then. Kādas idejas?

Dens Rīds (autors) on December 11, 2017:

Thomas - It sounds like you're not getting enough air flow when the filter is in. Perhaps it's restricting the airflow just enough to make the unit overheat and shut down prior to satisfying the thermostat. Often when adding a high end air cleaner, the ducts coming to it need increased in size to allow for more air to keep the unit temperature within it's confines and not overheat the motor or exchanger. Hope this helps at least to understand what the issue MIGHT be. Paldies, ka lasījāt.

Thomas 2017. gada 10. decembrī:

If I remove the air filter on my electric furnace then I heat until it reaches the Nest thermostat selected target temperature. If I place the air filter in, it doesn’t reach the selected temperature but is about 4 degrees colder. What is wrong and what is the fix?

Dens Rīds (autors) on December 08, 2017:

Dave - They can vary. The best way to know your range is to check the High Limit/Fan Switch. There is usually a temp range on there for your unit.

Deivs on December 05, 2017:

What should the heated air coming out of heat exchange Be is there a minimum temp ??? Like 120 deg ?

Dens Rīds (autors) 2017. gada 12. novembrī:

John - That's an odd one but likely an issue with communication between the stat and furnace. I'm sorry but can't offer much there other than rechecking your programming and running electrical tests to see what's making the unit shut down in that first cycle.

John Beattie on November 11, 2017:

My gas furnace comes on for the 1st program cycle of the morning but doesn't complete the cycle and will stop with out reaching the programed setting. If I turn the furnace on/off it then acts like it completes a heat cycle without the burners on. Then in a minute or so later the furnace comes on and then regularly runs the rest of the day. what might be wrong?

Dens Rīds (autors) on November 10, 2017:

Ozzie - A high efficient furnace has an intake and exhaust pipe and connection usually. Sometimes guys will let the unit pull air from in the home on the intake and not run it all the way outside. In order to do that, they are supposed to make sure there is enough free square footage to provide the needed intake. Taking that door off may be giving you just enough to do the job but you shouldn't have to leave any covers off your unit to make it run. Ceru, ka tas palīdzēs.

OzzieSch on November 10, 2017:

What exactly brings in the outside air for an efficient furnace? I don't get enough outside air to combust the gas. When I take off a little side cover on the furnace to let in inside air, the furnace works properly. What is my problem?

Dens Rīds (autors) on November 08, 2017:

Lee - If that's the case then they may need a good cleaning. I'm a little stunned though since a flame sensor should detect that the burners aren't lit since one needs to fire to fire the next and the next. ???

Dens Rīds (autors) on November 06, 2017:

Marco - I'm sorry but for me to help I would have to perform electrical circuit testing to pinpoint your problem here. I would start with the thermostat. Sounds like it may be suspect.

Dens Rīds (autors) 2017. gada 2. novembrī:

Thank you Jonas!

Jonas Porter 2017. gada 1. novembrī:

This was just an awesome explanation. Paldies. Paldies.

Dens Rīds (autors) on October 21, 2017:

Kevin - There is obviously a short somewhere. Likely culprits are the transformer and/or entire board. There could be other causes but this is what I'd suspect. Paldies, ka lasījāt.

Trina Bowers on October 19, 2017:

Ok i checked the fuse, i clean the heating sensor and the blower is working, glow ignitor comes on, slow flashing green light. I checked the thermostat ....the problem is i cant seem to get a flame ignited i dint know what else to do...i want to call for help to be my last resort.

Jw clink on October 19, 2017:

I replaced my ignition last year and furnace work fine.

This year it will not even get hot.

Fan works fine.

Kāda ideja?

Kevin Zoch on October 17, 2017:

I have a Trane Furnace that I determined has a blown fuse on the control panel. When I replace the fuse and push the black switch that the metal panel touches it instantly blows again.

Ārons on October 13, 2017:

I have a Colman Evcon. It is flashing 4 flashes meaning bad limit switch. Tested all switches and checked out. Have a green flash when unit not heating. Bad board?

Dens Rīds (autors) on October 07, 2017:

Duane - It sounds like it. If the inducer fan/motor is shot then nothing will work as it's the first step in the heating cycle and if it is bad, the whole assembly is usually sold as a piece and is typically specific to it's brand so universal parts aren't likely going to be an option for repair. You'll need to find the distributor for your brand of furnace to find the part most likely. Paldies, ka lasījāt.

Duane on October 06, 2017:

The induction fan does not start it just hums. It does not spin. Is the fan bad or is there something else I should look for?

Dens Rīds (autors) 2017. gada 11. septembrī:

Amacblue - The coil sits on top of the furnace. It's not part of the furnace. It is not always possible for a homeowner to do this since sometimes there is not way to access the underneath of the coil where dirt and such collects in which case it would need to be removed and that DEFINITELY requires a service technician. If you can however access the underside, congrats and it should be cleaned but carefully and not to bend the fins over so that air can't pass through. Paldies, ka lasījāt.

Amacblue 2017. gada 8. septembrī:

I would like to clean my coil on my furnace however o can't seem to locate it. It is a carrier just like the one pictured thank you

Dens Rīds (autors) on July 05, 2017:

Luis - You may have a blown fuse on the board. It's usually 3 amp fuse that is like that in a car. Can't say for sure but that's where I would start. Thank you for reading.

Dens Rīds (autors) on March 26, 2017:

Robby =- There is a laundry list of things to check from here however it doesn't seem coincidental that this is happening after the stat was changed. Sounds like perhaps your white wire isn't making good contact or in the right spot. Double check your stat wiring. Beyond that, there are too many things to check to list here. Fuse on board? Gas valve? Ignitor bad? Limt? Pressure Switch? I'm sorry I can't be more helpful from here. Paldies, ka lasījāt.

robby on March 25, 2017:

My heater stopped working yesterday nigh (it had stopped once few months ago, we changed the thermostat battery and it worked fine). After it stopped working, I put a new thermostat and still no luck. These are the few observations, please help in letting me know what is wrong

1) the AC works fine with both thermostat. The AC turns on (outside the house) and the blower blows air

2)On heat, the fan ON position gets the blower working (and you can hear the blower unit below the furnace making noise).

2)On heat, auto, nothing is working. The blower does not work, the flame is not lit (however the pilot flame is lit fine)

While changing to new thermostat, twice on Heat/AUTO, the blower came on but it kept pushing cold air for minutes. Now even that is not happening. Manually pushing the switch in the furnace gets the blower going, but there is no furnace flame(only pilot flame).

Please let me know what to do next

Dens Rīds (autors) on March 08, 2017:

Arash - It sounds like you had/have a short circuit somewhere. If you don't have a voltmeter you will have a very hard time finding it. You may want to call a tech or you could find yourself spending a lot of money on parts you don't need or buying a part that will short again because you didn't identify the source. Thank you for reading.

Arash on March 07, 2017:

Hi Daniel, I have a Lennox hvac with two zone. My heater stopped working last month an no power on thermostats. I notice the fuse on zone controller board is blown. I changed the fuse with a 5 amp. The power return to thermostats but heater didn't turned on again. I ordere a new zone controller but again the fuse blown in new board. So I thought the problem is from main controller board. I ordered and replaced the main controller plus adaptor. Still heater doesn't work. The egniter glows but the gas valve doesn't release gas to flame. I checked the voltage on gas valve and it's not 24v. It keeps trying ignite and doesn't go to watch guard mode. Would you please help me to figure it up? Paldies

Ccole456 on February 21, 2017:

Paldies. I looks up the difference and it appears it is an ignition board. Thanks for confirming. We have a number of things to try and hoping to keep the unit going for at least a few more months!

Dens Rīds (autors) on February 21, 2017:

If you have a spark ignition board then you perhaps will not have what I was thinking of. My apologies. There are so many boards out there and this was not what I was envisioning. It would be in plain site if you could change it and I don't believe you can open those without causing further damage.

Ccole456 on February 21, 2017:

Daniel- Curious if you can assist in locating the fuse on the board. The white Rogers control seems to be sealed. The fuse would be inside the case correct? The main fuse at the switch is fine we did check that one.

Dens Rīds (autors) on February 21, 2017:

Perhaps you've blown the fuse on the board. Typically a 3 or 5 amp automotive type fuse and/or perhaps the 120v/24v transformer took a hit. That could be the humming you hear. All of these are cheap places to start. I'm sorry but troubleshooting over the net is very tough so I try to recommend some of the simplest, cheap repairs to folks.

Ccole456 on February 20, 2017:

Daniel Robbins thanks. Nothing we have read or viewed yet has led us to the capacitor. Haven't been able to make any of the initial trouble shooting techniques give us a clear yes or no. We had a number of power failures from wind the day before it stopped working. If I understand you the the old White Rodgers control panel should illuminate to indicate at least something.

We will look into the capacitor then probably need to call technician if that doesn't work?

Dens Rīds (autors) on February 20, 2017:

Ccole456 - Sounds like the main blower isn't turning and that humming may be the motor trying to start. There is a capacitor usually mounted to the blower housing that may be bad and would be a cheap easy place to start and if that doesn't work, perhaps the blower is shot. That said, if the light on the board isn't lit, then you may have taken a hit electrically and then the potential possibilities get to be too many to cover here. That said, I would start at that capacitor. Paldies, ka lasījāt.

Ccole456 on February 19, 2017:

York gas furnace clicks on and then you hear a low continuous buzzing noise (seems to come from near the control panel) and nothing else happens. Replaced inducer motor thinking that was the problem, same issues.

Stat working and fan doesn't turn on when switched "on" at stat. Getting power where stat wires connect to pressure switch. Tubing at pressure switch appears unblocked and in good shape.

Could it be the pressure switch? Could it be the control panel? There is one light on control panel but it doesn't illuminate, no blink code, nothing. Could it be something else? Thoughts?

Džila on February 08, 2017:

Just replaced an oversized furnace with the right sized one as i was having issues with the furnance constantly coming on. I lowered the thermostat several degrees during the day so it would not come on as much. With the new furnace I thought this would all be resolved but it has not. It comes on more frequently and even with the temp set lower it comes on every 10 mins. Kāds padoms? I've been dealing with this for 2 years and I just want an answer!

Wayne Hogan on January 31, 2017:

Have a 2-stage furnace. furnace runs great on high, runs for about 2 minutes on low then gas shuts the gas valve and the cycle repeats many times till thermostat is met. I have replaced the roll out switch and flame rod and it still occurs. Kādi ieteikumi?

Chris taft 2017. gada 22. janvārī:

Carrier weathermaker has been having flame out problems, had a tech come out and tell me that the intake/exhaust wad too small and needed to be 3", so all that is changed and now it seems like it won't cycle back to back without having an issue. Turn power off to furnace and back on will work for 1 maybe 2 times. Any advice?

Dens Rīds (autors) 2017. gada 22. janvārī:

Michael Riemer - Not real sure. Could be too large of BTU. Could be the LP kit to make it LP wasn't adjusted properly. Could be a new stat is more accurate and the old one wasn't keeping the temp as consistent. Sorry but this is a tough one that would require further investigation onsite than I can provide here.